NSN: 5925-01-104-7974
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Fragility Factor
moderately rugged
-
Body Width
0.730 inches minimum and 0.780 inches maximum
-
Trip Release Method
magnetic single location
-
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
-
Special Handling Feature
magnetic
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
-
Terminal Type And Quantity
2 threaded stud
-
Case Material
plastic
-
Body Length
2.510 inches maximum
-
Frequency In Hertz
60.0 single location
-
~1
data on certain environmental and performanc
-
Body Style
single pole type
-
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac single location
-
Specification/Standard Data
81349-mil-c-55629/1 government specification
-
Boss Height
0.140 inches nominal
-
Inclosure Protection Type For Which Designed
moisture resistant and shock resistant and vibration resistant
-
Arc Quenching Method
magnetic blowout
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Trip Release Characteristic
time delay single location
-
Nominal Thread Size
0.138 inches
-
Internal Trip Release Configuration
series trip single location
-
Manual Actuator Type And Quantity
1 toggle
-
Pole Quantity
1
-
Mounting Surface To Terminal End Distance
2.553 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
2 threaded hole
-
Actuator Function
trip-reset
-
Storage Type
general purpose warehouse
-
Actuator Position Designation
at pole one
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
-
Thread Series Designator
unc
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.050 minimum at 200 pct single location and 10.000 maximum at 200 pct single location
Related Parts by Category
Related Manufacturers


AS6081 Methods