NSN: 5925-01-117-5628

Technical Characteristics

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Manual Actuator Type And Quantity

    3 toggle

  • Unpackaged Unit Weight

    11.100 ounces

  • Case Material

    plastic

  • Inclosure Protection Type For Which Designed

    moisture resistant and fungus resistant and salt spray proof and shock resistant and vibration resistant

  • Terminal Type And Quantity

    6 threaded stud

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Body Width

    2.265 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Thread Quantity Per Inch

    32

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 22.000 maximum at 200 pct all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Mounting Surface To Terminal End Distance

    2.490 inches maximum

  • Actuator Position Designation

    at each pole

  • Thread Series Designator

    unc

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...