NSN: 5925-01-123-6399
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
multipole-multiple actuator type
-
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
-
Switch Contact Arrangement
single pole, double throw
-
Mounting Facility Type And Quantity
6 threaded hole
-
Boss Height
0.125 inches minimum and 0.135 inches maximum
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Maximum Continuous Load Current Rating Per Pole
12.0 amperes ac all locations
-
Body Width
2.245 inches minimum and 2.255 inches maximum
-
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Center To Center Distance Between Terminals Parallel To Width
0.745 inches minimum and 0.755 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.655 inches minimum and 1.665 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Manual Actuator Type And Quantity
3 toggle
-
Switch Location And Position Designation
internal at pole one
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.745 inches minimum and 0.755 inches maximum
-
Case Material
plastic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Inclosure Protection Type For Which Designed
dustproof
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Mounting Surface To Terminal End Distance
1.835 inches minimum and 1.845 inches maximum
-
Reset Method
manual
-
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
-
Terminal Type And Quantity
6 tab, solder lug
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Thread Quantity Per Inch
32
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Trip Release Method
magnetic-hydraulic all locations
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations
Related Parts by Category
Related Manufacturers


AS6081 Methods