NSN: 5925-01-137-0159

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 all locations

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Surface To Terminal End Distance

    3.984 inches minimum and 4.016 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.578 inches minimum and 4.610 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    1.484 inches minimum and 1.516 inches maximum

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Body Length

    5.984 inches minimum and 6.016 inches maximum

  • Precious Material And Location

    terminal and contact surfaces silver

  • Bushing Length

    0.203 inches minimum and 0.235 inches maximum

  • Switch Voltage Rating And Type In Volts

    240.0 ac and 250.0 dc

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Switch Current Rating And Type In Amps

    15.0 ac and 0.25 dc

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Pole Quantity

    2

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Actuator Position Designation

    at pole one

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Center To Center Distance Between Terminals Parallel To Length

    5.109 inches minimum and 5.141 inches maximum

  • Actuator Function

    trip-reset

  • Switch Terminal Type

    wire lead

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Body Width

    2.984 inches minimum and 3.010 inches maximum

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Terminal Type And Quantity

    4 compression

  • Switch Location And Position Designation

    internal between pole one and two

  • Manual Actuator Type And Quantity

    1 toggle

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...