NSN: 5925-01-143-2451

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    70.000 minimum at 200 pct single location and 425.000 maximum at 200 pct single location

  • Trip Release Characteristic

    instantaneous single location and time delay single location

  • Terminal Type And Quantity

    2 compression

  • Frequency In Hertz

    60.0 single location

  • Body Style

    single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac single location and 250.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Method

    thermal-magnetic single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Boss Height

    0.250 inches nominal

  • Pole Quantity

    1

  • Body Width

    1.375 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    14000.0 ac single location and 10000.0 dc single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.874 inches nominal

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal single location

  • Body Length

    6.312 inches nominal

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Body Height

    3.187 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.874 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.125 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    140.0 single location

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...