NSN: 5925-01-158-4510
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
 - 
                                    
Boss Height
0.220 inches nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
125.0 dc single location
 - 
                                    
Unpackaged Unit Weight
9.000 ounces
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
70.0 amperes dc single location
 - 
                                    
Case Material
plastic
 - 
                                    
Terminal Type And Quantity
2 threaded stud
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
End Item Identification
lav, anti-tank
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Reset Method
manual
 - 
                                    
Actuator Position Designation
at pole one
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Criticality Code Justification
feat
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Special Features
weapon system essential
 - 
                                    
Mounting Facility Type And Quantity
2 threaded hole
 - 
                                    
Mounting Surface To Terminal End Distance
2.610 inches nominal
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Circuit Protection Type
overcurrent single location
 - 
                                    
Trip Release Method
thermal single location
 - 
                                    
Pole Quantity
1
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Internal Trip Release Configuration
series trip single location
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Trip Release Characteristic
time delay single location
 - 
                                    
Trip Delay Time In Seconds Per Rated Continuous Current
0.700 minimum at 200 pct single location and 20.000 maximum at 200 pct single location
 - 
                                    
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
3.550 inches nominal
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Body Length
5.800 inches nominal
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Body Width
1.013 inches nominal
 - 
                                    
Body Style
single pole type
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    