NSN: 5925-01-175-9298

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    multipole-multiple actuator type

  • Trip Release Method

    magnetic all locations

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 22.000 maximum at 200 pct all locations

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Mounting Surface To Terminal End Distance

    2.491 inches maximum

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Actuator Position Designation

    at each pole

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Switch Location And Position Designation

    internal at pole one

  • Unpackaged Unit Weight

    11.100 ounces

  • Switch Terminal Type

    quick disconnect, male

  • Manual Actuator Type And Quantity

    3 toggle

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Body Length

    2.480 inches minimum and 2.500 inches maximum

  • Inclosure Protection Type For Which Designed

    shock resistant and moisture resistant and fungus resistant and salt spray proof and vibration resistant

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Thread Series Designator

    iso s

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    277.0 ac all locations

  • Thread Pitch In Millimeters

    0.50

  • Arc Quenching Method

    magnetic blowout

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    3.0 millimeters

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Body Width

    2.265 inches maximum

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Contact Arrangement

    single pole, double throw

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...