NSN: 5925-01-187-6121

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Unpackaged Unit Weight

    3.600 ounces

  • Terminal Type And Quantity

    6 wire hook

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Thread Series Designator

    unef

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct and 6.000 maximum at 200 pct first location

  • Internal Trip Release Configuration

    series trip first location

  • Internal Trip Release Configuration

    relay trip second location

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0

  • Trip Release Method

    magnetic all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    2

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Case Material

    metal

  • Body Width

    1.281 inches maximum

  • Body Length

    1.562 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Nominal Thread Size

    0.375 inches

  • Actuator Position Designation

    between pole one and two

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay first location

  • Trip Release Characteristic

    instantaneous second location

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 milliamperes dc second location

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes dc first location

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Body Style

    1b multipole-single actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...