NSN: 5925-01-216-5225
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performanc
-
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Trip Release Method
magnetic single location
-
Terminal Type And Quantity
2 wire hook
-
Bushing Length
0.332 inches minimum and 0.380 inches maximum
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches minimum and 0.906 inches maximum
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Body Length
1.531 inches minimum and 1.562 inches maximum
-
Specification/Standard Data
81349-mil-c-39019/1 government specification
-
Circuit Protection Type
overcurrent single location
-
Body Width
0.594 inches minimum and 0.625 inches maximum
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Pole Quantity
1
-
Case Material
metal
-
Manual Actuator Type And Quantity
1 toggle
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
-
Body Style
single pole type
-
Mounting Surface To Terminal End Distance
1.669 inches minimum and 1.700 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
1.25 amperes dc single location
-
Thread Series Designator
unef
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct single location
Related Parts by Category
Related Manufacturers
Certified toAS6081 Methods