NSN: 5925-01-260-3739

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Boss Height

    0.115 inches minimum and 0.145 inches maximum

  • Storage Type

    general purpose warehouse

  • Inclosure Protection Type For Which Designed

    salt spray proof and moisture resistant and shock resistant and vibration resistant

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.645 inches minimum and 1.675 inches maximum

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Unpackaged Unit Weight

    2.200 ounces

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes dc single location

  • Arc Quenching Method

    magnetic blowout

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Body Style

    single pole type

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct single location and 10.000 maximum at 200 pct single location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...