NSN: 5925-01-270-1612

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    0.738 inches minimum and 0.758 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    100.0 milliamperes dc single location

  • Trip Release Method

    magnetic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Actuator Function

    trip-reset

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Internal Trip Release Configuration

    series trip single location

  • Bushing Length

    0.235 inches minimum and 0.255 inches maximum

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.672 inches minimum and 1.712 inches maximum

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    18

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push button

  • Actuator Position Designation

    at pole one

  • Nominal Thread Size

    0.312 inches

  • Switch Terminal Type

    tab, solder lug

  • Terminal Type And Quantity

    2 tab, solder lug

  • Body Style

    1a single pole type

  • Body Length

    1.622 inches minimum and 1.636 inches maximum

  • Body Width

    0.551 inches minimum and 0.591 inches maximum

  • Switch Location And Position Designation

    internal at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 200 pct single location and 50.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    corrosion resistant and humidity resistant and fungus resistant

  • Switch Current Rating And Type In Amps

    5.0 ac

  • Switch Voltage Rating And Type In Volts

    250.0 ac

  • Unpackaged Unit Weight

    30.000 ounces

  • Thread Series Designator

    unc

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...