NSN: 5925-01-289-2082

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    2a single pole type

  • Body Length

    1.385 inches maximum

  • Body Width

    0.670 inches minimum and

  • Body Width

    0.690 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.155 inches maximum

  • Mounting Surface To Terminal End Distance

    1.672 inches minimum and

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes dc single location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Frequency In Hertz

    50.0 or

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    un

  • Iii Storage Type

    general purpose warehouse

  • Bushing Length

    0.458 inches minimum and

  • Bushing Length

    0.478 inches maximum

  • Body Length

    1.365 inches minimum and

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    0.095 inches minimum and

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    1.732 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac and

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.500 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Terminal Type And Quantity

    2 tab, solder lug

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...