NSN: 5925-01-294-4660
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
8c multipole-multiple actuator type
-
Body Length
2.510 inches maximum
-
Body Width
1.469 inches minimum and 1.531 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.779 inches minimum and 1.841 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.719 inches minimum and 0.781 inches maximum
-
Switch Contact Arrangement
single pole, double throw
-
Mounting Surface To Terminal End Distance
2.553 inches maximum
-
Pole Quantity
2
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes dc all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc all locations
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic all locations
-
Reset Method
manual
-
Manual Actuator Type And Quantity
2 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at each pole
-
External Actuator Linkage Arrangement
one and two linked
-
Internal Trip Release Configuration
series trip all locations
-
Switch Location And Position Designation
internal at pole one
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.130 minimum at 200 pct all locations and 1.400 maximum at 200 pct
-
Inclosure Protection Type For Which Designed
fungus resistant and humidity resistant
-
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
-
Test Data Document
81349-mil-c-55629 specification
-
Thread Series Designator
unc
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.076 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.719 inches minimum and 0.781 inches maximum
-
Boss Height
0.109 inches minimum and 0.171 inches maximum
-
Mounting Facility Type And Quantity
4 threaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Trip Release Characteristic
time delay all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Auxiliary Switch Function And Quantity
1 alarm
-
Nominal Thread Size
0.138 inches
-
Switch Terminal Type
tab, solder lug
-
Switch Current Rating And Type In Amps
10.0 ac and 1.0 dc
-
Terminal Type And Quantity
4 threaded stud
-
Specification/Standard Data
81349-mil-c-55629/4 government specification
Related Parts by Category
Related Manufacturers


AS6081 Methods