NSN: 5925-01-295-8442

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +150.0/+500.0 ac all locations and +150.0/+500.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Length

    9.000 inches nominal

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Terminal Type And Quantity

    6 compression

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations and 50.0 amperes dc all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations and 10000.0 dc all locations

  • Case Material

    plastic

  • Actuator Position Designation

    at pole two

  • Body Height

    4.062 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Unthreaded Mounting Hole Diameter

    0.250 inches nominal

  • Trip Release Method

    magnetic all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Body Length

    10.000 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Features Provided

    adjustable trip release

  • Reset Method

    manual

  • Body Width

    4.125 inches nominal

  • Inclosure Protection Type For Which Designed

    dustproof

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Trip Release Characteristic

    instantaneous all locations

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...