NSN: 5925-01-296-5360

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performanc

  • Case Material

    plastic

  • Trip Release Method

    magnetic single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Inclosure Protection Type For Which Designed

    dustproof

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Bushing Length

    0.593 inches minimum and 0.657 inches maximum

  • Fragility Factor

    moderately rugged

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Nonturn Device Diameter

    0.138 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Thread Quantity Per Inch

    32

  • Center To Center Distance Between Terminals Parallel To Length

    1.498 inches minimum and 1.562 inches maximum

  • Specification/Standard Data

    81349-mil-c-55629/20 government specification

  • Circuit Protection Type

    overcurrent single location

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Length

    1.968 inches minimum and 2.032 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    400.0 single location

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Body Style

    single pole type

  • Nonturn Device Radius

    0.641 inches minimum and 0.671 inches maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Terminal Type And Quantity

    2 tab w/screw

  • Thread Series Designator

    un

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct single location and 5.800 maximum at 200 pct single location

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac single location

  • Nonturn Device Length

    0.115 inches minimum and 0.145 inches maximum

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...