NSN: 5925-01-311-2502

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    metal

  • Body Length

    1.500 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Switch Terminal Type

    eyelet

  • Inclosure Protection Type For Which Designed

    hermetically sealed and shock resistant and vibration resistant

  • Switch Location And Position Designation

    internal at pole three

  • Nominal Thread Size

    0.375 inches

  • Actuator Function

    trip-reset

  • Reset Method

    manual

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and 500.0 dc all locations

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Pole Quantity

    3

  • Iii Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole, double throw

  • Iii Nonturn Device Diameter

    0.109 inches minimum and 0.171 inches maximum

  • Iii Nonturn Device Length

    0.063 inches minimum and 0.125 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.844 inches minimum and 0.906 inches maximum

  • Terminal Type And Quantity

    6 wire hook

  • Thread Series Designator

    unef

  • Internal Trip Release Configuration

    series trip all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    at pole two

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    17.5 amperes ac and 17.5 amperes dc all locations

  • Thread Quantity Per Inch

    32

  • Iii Special Handling Feature

    magnetic

  • Iii Storage Type

    general purpose warehouse

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Iii Nonturn Device Radius

    0.594 inches minimum and 0.656 inches maximum

  • Iii Nonturn Device Location

    at 3 oclock and at 9 oclock

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches minimum and 0.656 inches maximum

  • Body Width

    1.875 inches maximum

  • Bushing Length

    0.380 inches maximum

  • Body Style

    1b multipole-single actuator type

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...