NSN: 5925-01-311-3090

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Trip Release Characteristic

    instantaneous all locations

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Reset Method

    manual

  • Features Provided

    adjustable trip release

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +1500.0/+3000.0 ac all locations and +1500.0/+3000.0 dc all locations

  • Maximum Continuous Load Current Rating Per Pole

    300.0 amperes ac all locations and 300.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 250.0 dc all locations

  • Case Material

    plastic

  • Unthreaded Mounting Hole Diameter

    0.196 inches nominal

  • Storage Type

    general purpose warehouse

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Actuator Function

    trip-reset

  • Body Length

    10.125 inches nominal

  • Body Width

    8.250 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.249 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Mounting Surface To Terminal End Distance

    3.812 inches nominal

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    22000.0 ac all locations and 10000.0 dc all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Arc Quenching Method

    magnetic blowout

  • Center To Center Distance Between Terminals Parallel To Length

    7.249 inches nominal

  • Boss Height

    0.219 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    2.750 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...