Technical Characteristics

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    275.0 ac single location and 60.0 dc single location

  • Overall Width

    1.807 inches nominal

  • Overall Length

    2.244 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac single location and 15.0 amperes dc single location

  • Terminal Type And Quantity

    2 quick disconnect, male

  • Frequency In Hertz

    60.0 single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    60.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    humidity resistant

  • Case Material

    plastic

  • Fragility Factor

    moderately rugged

  • Body Style

    rectangular dimensional envelope

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Unpackaged Unit Weight

    2.300 ounces

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac single location and 500.0 dc single location

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push button

  • Overall Height

    0.788 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...