NSN: 5925-01-315-1896
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
 - 
                                    
Actuator Position Designation
at pole two
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Unthreaded Mounting Hole Diameter
0.709 inches minimum and 0.729 inches maximum
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Terminal Type And Quantity
6 compression
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100000.0 ac all locations
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Trip Release Characteristic
instantaneous all locations
 - 
                                    
Pole Quantity
3
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
1600.0 amperes ac all locations
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Body Height
9.928 inches minimum and 9.948 inches maximum
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
4.021 inches minimum and 4.041 inches maximum
 - 
                                    
Reset Method
manual
 - 
                                    
Body Width
12.053 inches minimum and 12.073 inches maximum
 - 
                                    
Features Provided
adjustable trip release
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Actuator Function
trip-reset
 - 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
19.866 inches minimum and 19.886 inches maximum
 - 
                                    
Trip Release Method
magnetic all locations
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
14.428 inches minimum and 14.448 inches maximum
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
4.021 inches minimum and 4.041 inches maximum
 - 
                                    
Case Material
plastic
 - 
                                    
Arc Quenching Method
magnetic blowout
 - 
                                    
Adjustable Trip Setting Current Range Per Pole In Amps
+3200.0/+12800.0 ac all locations
 - 
                                    
Inclosure Protection Type For Which Designed
general purpose
 - 
                                    
Boss Height
0.740 inches minimum and 0.760 inches maximum
 - 
                                    
Body Length
22.115 inches minimum and 22.260 inches maximum
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    