NSN: 5925-01-316-3407

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    1c multipole-multiple actuator type

  • Bushing Length

    0.099 inches minimum and

  • Body Length

    2.281 inches maximum

  • Body Width

    1.969 inches minimum and

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.591 inches maximum

  • Bushing Length

    0.161 inches maximum

  • Body Length

    2.219 inches minimum and

  • Body Width

    2.031 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.529 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Width

    1.629 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Width

    1.691 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.629 inches minimum and

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Pole Quantity

    3

  • Iii Arc Quenching Method

    magnetic blowout

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Position Designation

    at each pole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct and

  • Frequency In Hertz

    400.0 all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.719 inches minimum and

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.781 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.691 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.900 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Definitive Government Spec/Std Reference

    m55629/11-062

  • Manufacturers Code

    81349

  • Non-Definitive Government Spec/Std Reference

    mil-c-55629/11

  • Test Data Document

    81349-mil-c-55629 specification

  • Thread Series Designator

    unc

  • Specification/Standard Data

    81349-mil-c-55629/11 government specification

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...