Technical Characteristics

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.760 inches minimum and

  • Body Width

    0.780 inches maximum

  • Boss Height

    0.940 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 clip

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Frequency In Hertz

    50.0 or

  • Frequency In Hertz

    60.0 single location

  • Body Style

    10a single pole type

  • Body Length

    1.550 inches minimum and

  • Body Length

    1.570 inches maximum

  • Body Height

    1.810 inches minimum and

  • Body Height

    1.870 inches maximum

  • Case Material

    plastic

  • Iii Fragility Factor

    moderately rugged

  • Boss Height

    0.920 inches minimum and

  • Pole Quantity

    1

  • Iii Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac and

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac and

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    dustproof

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...