NSN: 5925-01-325-3221

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    1.969 inches minimum and 2.031 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.529 inches minimum and 1.591 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.719 inches minimum and 0.781 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Body Style

    8c multipole-multiple actuator type

  • Body Width

    2.219 inches minimum and 2.281 inches maximum

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.719 inches minimum and 0.781 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.629 inches minimum and 1.691 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.099 inches minimum and 0.161 inches maximum

  • Mounting Surface To Terminal End Distance

    2.032 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Specification/Standard Data

    81349-mil-c-55629/11 government specification

  • Thread Series Designator

    unc

  • Test Data Document

    81349-mil-c-55629 specification

  • Frequency In Hertz

    400.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.150 minimum at 200 pct all locations and 1.900 maximum at 200 pct

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    3 toggle

  • Terminal Type And Quantity

    6 tab w/screw

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...