NSN: 5925-01-325-4361
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
2 clip
-
Fragility Factor
moderately rugged
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct first location and 1.700 maximum at 200 pct first location
-
Special Handling Feature
magnetic
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes dc third location
-
Frequency In Hertz
50.0 second location or 60.0 second location
-
Reset Method
manual
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Body Length
2.000 inches nominal
-
Internal Trip Release Configuration
series trip all locations
-
Unpackaged Unit Weight
3.900 ounces
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac first location
-
Body Height
1.770 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.595 inches minimum and 0.655 inches maximum
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc third location
-
Actuator Position Designation
at pole two
-
Boss Height
0.005 inches minimum and 0.155 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac first location
-
Body Style
multipole-single actuator type
-
Manual Actuator Type And Quantity
1 rotary
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac first location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac second location
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac second location
-
Main Contact Tripping Mechanism Type
trip free
-
Body Width
2.170 inches nominal
-
Inclosure Protection Type For Which Designed
shockproof and vibrationproof
-
Terminal Type And Quantity
6 quick disconnect, male
-
Frequency In Hertz
50.0 first location or 60.0 first location
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac second location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct second location and 1.700 maximum at 200 pct second location
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc third location
-
Case Material
plastic
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct third location and 9.000 maximum at 200 pct third location
Related Parts by Category
Related Manufacturers


AS6081 Methods