NSN: 5925-01-336-6383
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Nonturn Device Diameter0.250 inches nominal 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Reset Methodmanual 
- 
                                    Mounting Facility Type And Quantity1 threaded bushing w/panel seal 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.625 inches nominal 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps1000.0 ac all locations 
- 
                                    Nonturn Device Length0.005 inches minimum and 0.015 inches maximum 
- 
                                    Inclosure Protection Type For Which Designedshock resistant and vibration resistant and hermetically sealed 
- 
                                    Nominal Thread Size0.375 inches 
- 
                                    Thread Quantity Per Inch32 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac all locations 
- 
                                    Trip Release Methodmagnetic all locations 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Center To Center Distance Between Terminals Parallel To Length0.875 inches nominal 
- 
                                    Nonturn Device Locationat 3 oclock and at 9 oclock 
- 
                                    Body Stylemultipole-single actuator type 
- 
                                    Case Materialmetal 
- 
                                    Cubic Measure8.941 cubic inches 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Body Width1.937 inches maximum 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent115.0 all locations 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Specification/Standard Data29957-5114-1803 manufacturers specification control 
- 
                                    Body Length1.562 inches maximum 
- 
                                    Maximum Continuous Load Current Rating Per Pole15.0 amperes ac all locations 
- 
                                    Frequency In Hertz400.0 all locations 
- 
                                    Thread Series Designatorunef 
- 
                                    Terminal Type And Quantity6 tab w/screw 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations 
- 
                                    Mounting Surface To Terminal End Distance1.950 inches maximum 
- 
                                    Bushing Length0.380 inches maximum 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    