NSN: 5925-01-340-1185
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performanc
-
Case Material
plastic
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac third location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac second location
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes dc first location
-
Manual Actuator Type And Quantity
3 toggle
-
Body Width
2.040 inches minimum and 2.245 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
20.000 maximum at 200 pct third location
-
Body Length
2.630 inches maximum
-
Specification/Standard Data
81349-mil-c-55629/5 government specification
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct second location and 3.000 minimum at 200 pct third location and 0.600 minimum at 200 pct first location and 20.000 maximum at 200 pct second location
-
Terminal Type And Quantity
6 threaded stud
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac second location
-
Fragility Factor
moderately rugged
-
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac third location
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.016 inches minimum and 2.062 inches maximum
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc first location
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Frequency In Hertz
60.0 second location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Mounting Surface To Terminal End Distance
2.553 inches maximum
-
Mounting Facility Type And Quantity
6 threaded hole
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
8.000 maximum at 200 pct first location
-
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac second location
-
Nominal Thread Size
0.138 inches
-
Inclosure Protection Type For Which Designed
dustproof and fungus proof
-
Main Contact Tripping Mechanism Type
trip free
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
-
Arc Quenching Method
magnetic blowout
-
Center To Center Distance Between Terminals Parallel To Length
1.810 inches nominal
-
Boss Height
0.140 inches nominal
-
Frequency In Hertz
60.0 third location
-
Test Data Document
81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
Related Parts by Category
Related Manufacturers


AS6081 Methods