NSN: 5925-01-349-0025
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Fragility Factormoderately rugged 
- 
                                    Trip Release Characteristicinstantaneous all locations 
- 
                                    Special Handling Featuremagnetic 
- 
                                    Pole Quantity3 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Maximum Continuous Load Current Rating Per Pole50.0 amperes ac all locations 
- 
                                    Body Stylerectangular dimensional envelope 
- 
                                    Reset Methodmanual 
- 
                                    Overall Width3.000 inches nominal 
- 
                                    Storage Typegeneral purpose warehouse 
- 
                                    Trip Release Ambient Temp Rating40.0 deg celsius nominal all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Case Materialplastic 
- 
                                    Overall Height4.496 inches nominal 
- 
                                    Inclosure Protection Type For Which Designedfungus proof 
- 
                                    Arc Quenching Methodmagnetic blowout 
- 
                                    Mounting Facility Type And Quantity4 unthreaded hole 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Terminal Type And Quantity6 compression 
- 
                                    Frequency In Hertz60.0 all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps10000.0 ac all locations 
- 
                                    Manual Actuator Type And Quantity1 toggle 
- 
                                    Overall Length6.344 inches nominal 
- 
                                    Actuator Position Designationat pole two 
- 
                                    Trip Release Methodthermal-magnetic all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent125.0 all locations 
- 
                                    Unthreaded Mounting Hole Diameter0.250 inches nominal 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac all locations 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    