Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 125 pct all locations and 120.000 maximum at 125 pct and 3.000 minimum at 200 pct and 20.000 maximum at 200 pct and 0.300 minimum at 400 pct and 2.300 maximum at 400 pct and 0.130 minimum at 600 pct and 1.000 maximum at 600 pct and

  • Trip Release Duty Cycle

    continuous all locations

  • Actuator Position Designation

    at pole two

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.530 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    2.232 inches nominal

  • Case Material

    metal

  • Body Height

    2.102 inches nominal

  • Body Width

    1.515 inches nominal

  • Bushing Length

    0.625 inches nominal

  • Terminal Type And Quantity

    4 screw

  • Thread Series Designator

    unc

  • Test Data Document

    81349-mil-c-55629b specification

  • Frequency In Hertz

    60.0 all locations

  • Special Features

    no auxiliary contacts

  • Thread Tolerance Class

    2b internal

  • Trip Release Ambient Temp Rating

    -40.0 deg celsius minimum all locations and 85.0 deg celsius maximum

  • ~1

    0.001 minimum at 800 pct and 0.600 maximum at 800 pct and 0.001 minimum at 1000 pct and 0.290 maximum at 1000 pct

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 toggle

  • Ultimate Trip Time Per Pole In Seconds

    1.000 minimum all locations and 500.000 maximum

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Pole Quantity

    2

  • Body Length

    2.000 inches nominal

  • Body Style

    6b multipole-single actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...