NSN: 5925-01-375-1254

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    6b multipole-single actuator type

  • Body Length

    2.000 inches nominal

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    2.323 inches nominal

  • Pole Quantity

    2

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Ultimate Trip Time Per Pole In Seconds

    1.000 minimum all locations and 500.000 maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Release Ambient Temp Rating

    -40.0 deg celsius minimum all locations and 85.0 deg celsius maximum

  • Thread Tolerance Class

    2b internal

  • Frequency In Hertz

    60.0 all locations

  • Test Data Document

    81349-mil-c-55629b specification

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    4 screw

  • Body Height

    2.102 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.530 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    nontrip free

  • Actuator Function

    trip-reset

  • Trip Release Duty Cycle

    continuous all locations

  • ~1

    0.001 minimum at 800 pct and 0.600 maximum at 800 pct and 0.001 minimum at 1000 pct and 0.290 maximum at 1000 pct

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 125 pct all locations and 120.000 maximum at 125 pct and 3.000 minimum at 200 pct and 20.000 maximum at 200 pct and 0.300 minimum at 400 pct and 2.300 maximum at 400 pct and 0.130 minimum at 600 pct and 1.000 maximum at 600 pct and

  • Special Features

    no auxiliary contacts

  • Bushing Length

    0.625 inches nominal

  • Body Width

    1.515 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...