NSN: 5925-01-375-6608
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency In Hertz
60.0 all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
nontrip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole two
-
Trip Release Duty Cycle
continuous all locations
-
~1
0.001 minimum at 800 pct and 0.600 maximum at 800 pct and 0.001 minimum at 1000 pct and 0.290 maximum at 1000 pct
-
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 125 pct all locations and 120.000 maximum at 125 pct and 3.000 minimum at 200 pct and 20.000 maximum at 200 pct and 0.300 minimum at 400 pct and 2.300 maximum at 400 pct and 0.130 minimum at 600 pct and 1.000 maximum at 600 pct and
-
Trip Release Ambient Temp Rating
-40.0 deg celsius minimum all locations and 85.0 deg celsius maximum
-
Special Features
no auxiliary contacts
-
Terminal Type And Quantity
4 screw
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Characteristic
time delay all locations
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.138 inches
-
Thread Tolerance Class
2b internal
-
Test Data Document
81349-mil-c-55629b specification
-
Thread Series Designator
unc
-
Body Style
6b multipole-single actuator type
-
Body Height
2.102 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
1.530 inches nominal
-
Maximum Continuous Load Current Rating Per Pole
7.5 amperes ac all locations
-
Bushing Length
0.625 inches nominal
-
Body Length
2.000 inches nominal
-
Body Width
1.515 inches nominal
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Length
2.232 inches nominal
-
End Item Identification
display equip.
-
Pole Quantity
2
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Trip Release Method
magnetic all locations
-
Ultimate Trip Time Per Pole In Seconds
1.000 minimum all locations and 500.000 maximum
Related Parts by Category
Related Manufacturers


AS6081 Methods