NSN: 5925-01-377-3076
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Internal Trip Release Configuration
series trip all locations
 - 
                                    
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations
 - 
                                    
Mounting Facility Type And Quantity
4 threaded hole
 - 
                                    
Thread Quantity Per Inch
32
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations and 20.0 amperes dc all locations
 - 
                                    
Trip Release Method
magnetic-hydraulic all locations
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Manual Actuator Type And Quantity
1 toggle
 - 
                                    
Nominal Thread Size
0.138 inches
 - 
                                    
Actuator Function
reset
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.938 inches nominal
 - 
                                    
Trip Release Characteristic
instantaneous all locations
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Pole Quantity
2
 - 
                                    
Thread Series Designator
unc
 - 
                                    
Reset Method
manual
 - 
                                    
Frequency In Hertz
60.0 all locations
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations and 5000.0 dc all locations
 - 
                                    
End Item Identification
panel, ac distb., p/n 2009-002-01 used onboard 47 ft mlb coast guard vessels
 - 
                                    
Main Contact Tripping Mechanism Type
trip free
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
 - 
                                    
Body Length
2.500 inches nominal
 - 
                                    
Boss Height
0.140 inches nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 65.0 dc all locations
 - 
                                    
Terminal Type And Quantity
4 threaded stud
 - 
                                    
Mounting Surface To Terminal End Distance
2.481 inches nominal
 - 
                                    
Body Width
1.500 inches nominal
 - 
                                    
Case Material
plastic
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    