NSN: 5925-01-436-2421

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Specification/Standard Data

    81349-mil-c-55629 government specification

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Thread Series Designator

    unc

  • Reset Method

    manual

  • Internal Trip Release Configuration

    relay trip single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.513 inches nominal

  • Body Width

    2.380 inches nominal

  • Actuator Function

    trip-reset

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.100 minimum at 200 pct single location and 10.500 maximum at 200 pct single location

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Pole Quantity

    1

  • Terminal Type And Quantity

    2 threaded stud and 3 turret

  • Switch Contact Arrangement

    single pole, single throw, normally closed

  • Center To Center Distance Between Terminals Parallel To Length

    3.647 inches nominal

  • Body Style

    single pole type

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 single location

  • Mounting Surface To Terminal End Distance

    3.140 inches nominal

  • Frequency In Hertz

    60.0 single location

  • Body Length

    4.750 inches nominal

  • Boss Height

    0.220 inches nominal

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Trip Release Method

    magnetic single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...