NSN: 5925-01-441-8995
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
~1
data on certain environmental and performanc
-
Test Data Document
81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Mounting Surface To Terminal End Distance
1.700 inches maximum
-
Bushing Length
0.380 inches maximum
-
Thread Series Designator
unef
-
Specification/Standard Data
81349-mil-c-39019/231s government specification
-
Body Width
0.625 inches maximum
-
Body Style
single pole type
-
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
-
Frequency In Hertz
400.0 single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
-
Body Length
1.562 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac single location
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Characteristic
time delay single location
-
Internal Trip Release Configuration
series trip single location
-
Manual Actuator Type And Quantity
1 toggle
-
Case Material
metal
-
Pole Quantity
1
-
Inclosure Protection Type For Which Designed
fungus resistant
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Circuit Protection Type
overcurrent single location
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location
-
Nominal Thread Size
0.375 inches
-
Thread Pitch Diameters
+0.3503/+0.3537 inches
-
Terminal Type And Quantity
4 screw
-
Actuator Function
trip-reset
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct single location and 9.000 maximum at 200 pct single location and 0.240 maximum at 400 pct single location
-
Actuator Position Designation
at pole one
-
Ultimate Trip Time Per Pole In Seconds
0.200 minimum single location and 7.000 maximum single location
-
Reset Method
manual
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
-
Trip Release Method
magnetic single location
Related Parts by Category
Related Manufacturers


AS6081 Methods