NSN: 5925-01-441-9569

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Ambient Temp Rating

    -40.0 deg celsius minimum all locations and 85.0 deg celsius maximum all locations

  • Switch Contact Arrangement

    double pole, single throw, normally open

  • Ultimate Trip Time Per Pole In Seconds

    0.500 nominal all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Width

    2.265 inches nominal

  • Bushing Length

    0.625 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    quick disconnect, male

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Mounting Facility Type And Quantity

    threaded bushing w/panel seal

  • Trip Release Duty Cycle

    continuous all locations

  • Internal Trip Release Configuration

    series trip w/dual rating first location

  • Center To Center Distance Between Terminals Parallel To Length

    1.530 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations

  • Mounting Surface To Terminal End Distance

    2.232 inches nominal

  • Frequency In Hertz

    400.0 all locations

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    10.0 ac nominal third location

  • Thread Series Designator

    unef

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Thread Tolerance Class

    2b external

  • Actuator Position Designation

    at pole two

  • Body Style

    multipole-single actuator type

  • Nominal Thread Size

    32.000 inches

  • Case Material

    metal

  • Internal Trip Release Configuration

    series trip second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 nominal at 150 pct all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole three

  • End Item Identification

    f15i lantirn

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    2.000 inches nominal

  • Internal Trip Release Configuration

    series trip w/auxiliary load terminal third location

  • Trip Release Method

    magnetic all locations

  • Auxiliary Switch Function And Quantity

    alarm

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...