NSN: 5925-01-442-7232

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Frequency In Hertz

    60.0 all locations or 400.0 all locations

  • Mounting Surface To Terminal End Distance

    1.819 inches minimum and 1.950 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    0.5 amperes ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 135 pct all locations and 60.000 maximum at 135 pct all locations

  • Thread Series Designator

    unef

  • Body Width

    1.250 inches minimum and 1.281 inches maximum

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Internal Trip Release Configuration

    series trip all locations

  • Terminal Type And Quantity

    4 screw

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches minimum and 0.906 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 50.0 dc all locations

  • Specification/Standard Data

    81349-mil-c-39019/03 government specification

  • Nominal Thread Size

    0.375 inches

  • Body Length

    1.531 inches minimum and 1.562 inches maximum

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.000 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...