NSN: 5925-01-450-6198

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Series Designator

    unef

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac and 500.0 dc single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Mounting Facility Type And Quantity

    threaded bushing w/panel seal

  • Body Style

    2a single pole type

  • Body Width

    0.625 inches maximum

  • Thread Quantity Per Inch

    32

  • Bushing Length

    0.380 inches maximum

  • Features Provided

    high inrush protection

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 9.000 maximum at 200 pct single location

  • Reset Method

    manual

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac and 50.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Frequency In Hertz

    400.0 single location

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Spec/Std Controlling Data

  • Body Length

    1.562 inches maximum

  • Specification/Standard Data

    81349-mil-c-39019/1 government specification

  • Main Contact Tripping Mechanism Type

    trip free

  • Case Material

    metal

  • Definitive Government Spec/Std Reference

    m39019/1-338s

  • Center To Center Distance Between Terminals Parallel To Length

    0.9006 inches maximum

  • Pole Quantity

    1

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac and 20.0 amperes dc single location

  • Actuator Position Designation

    at pole one

  • Manufacturers Code

    81349

  • Internal Trip Release Configuration

    series trip single location

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Actuator Function

    trip-reset

  • Test Data Document

    81349-mil-c-39019 specification

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    magnetic single location

  • Non-Definitive Government Spec/Std Reference

    mil-c-39019/01

  • Terminal Type And Quantity

    tab w/screw

  • Nominal Thread Size

    0.375 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...