NSN: 5925-01-466-7908

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    145.0 all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Body Length

    0.781 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Reset Method

    manual

  • Inclosure Protection Type For Which Designed

    shock resistant and vibration resistant

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac all locations

  • ~1

    data on certain environmental and performance

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Release Method

    thermal all locations

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    0.469 inches minimum and 0.531 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    200.0 ac all locations

  • Terminal Type And Quantity

    6 tab w/screw

  • Body Height

    1.381 inches maximum

  • Thread Series Designator

    un

  • Bushing Length

    0.219 inches minimum and 0.781 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.593 inches minimum and 0.655 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac all locations

  • Frequency In Hertz

    400.0 all locations

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Special Features

    auxiliary contacts are capable of carring 0.5 ampere lamp load 28 volds dc

  • Specification/standard Data

    96906-ms14154 government specification

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Body Style

    multipole-single actuator type

  • Body Width

    1.840 inches maximum

  • Actuator Position Designation

    at pole two

  • Manual Actuator Type And Quantity

    1 push-pull

  • Nominal Thread Size

    0.438 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...