NSN: 5925-01-513-1976

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.735 inches minimum and 0.765 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.925 inches minimum and 1.955 inches maximum

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Width

    3.015 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    2.530 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 minimum at 200 pct all locations and 22.000 maximum at 200 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.050 inches minimum and 2.070 inches maximum

  • Boss Height

    0.135 inches minimum and 0.165 inches maximum

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Mounting Surface To Terminal End Distance

    2.495 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Switch Contact Arrangement

    single pole, double throw

  • Switch Current Rating And Type In Amps

    10.0 ac and 3.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • End Item Identification

    an/sqq-89(v) 15 unit 735 & 762, pwr dist, receiver i/o & pwr dist, data prcsr

  • Terminal Type And Quantity

    8 threaded stud

  • Nominal Thread Size

    0.138 inches

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Frequency In Hertz

    50.0 all locations or 60.0 all locations

  • Switch Location And Position Designation

    internal at pole four

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations and 65.0 dc all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Terminal Type

    quick disconnect, male

  • Manual Actuator Type And Quantity

    4 toggle

  • Unpackaged Unit Weight

    14.800 ounces

  • Case Material

    plastic

  • Pole Quantity

    4

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...