NSN: 5925-01-517-3989
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    Special Featurestemp range m40.0 to 185.0 fah. tested iaw mil-std-202 methods 101, 106, 103 cond a, 213 cond i, 204, 301, 302. 
- 
                                    Circuit Protection Typeovercurrent all locations 
- 
                                    Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps5000.0 ac all locations and 5000.0 dc all locations 
- 
                                    Pole Quantity2 
- 
                                    Thread Series Designatorunc 
- 
                                    Actuator Position Designationat each pole 
- 
                                    Reset Methodmanual 
- 
                                    Trip Delay Time In Seconds Per Rated Continuous Current1.700 minimum at 200 pct all locations and 18.000 maximum at 200 pct all locations 
- 
                                    Part Name Assigned By Controlling Agencycircuit breaker 
- 
                                    Trip Release Characteristictime delay all locations 
- 
                                    Actuator Functiontrip-reset 
- 
                                    Internal Trip Release Configurationseries trip all locations 
- 
                                    Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent135.0 all locations 
- 
                                    Mounting Facility Type And Quantity4 threaded hole 
- 
                                    Center To Center Distance Between Terminals Parallel To Width0.719 inches minimum and 0.781 inches maximum 
- 
                                    Test Data Documentmil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data 
- 
                                    Maximum Continuous Load Current Rating Per Pole20.0 amperes ac all locations and 20.0 amperes dc all locations 
- 
                                    Trip Release Methodmagnetic-hydraulic all locations 
- 
                                    Body Stylemultipole-multiple actuator type 
- 
                                    Body Length2.469 inches minimum and 2.531 inches maximum 
- 
                                    Nominal Thread Size0.138 inches 
- 
                                    Mounting Surface To Terminal End Distance1.829 inches minimum and 1.891 inches maximum 
- 
                                    Operating Voltage Type And Rating Per Pole In Volts240.0 ac all locations and 80.0 dc all locations 
- 
                                    Main Contact Tripping Mechanism Typetrip free 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Length2.031 inches minimum and 2.093 inches maximum 
- 
                                    Distance Between Centerlines Of Mounting Facilities Parallel To Body Width0.719 inches minimum and 0.781 inches maximum 
- 
                                    Frequency In Hertz50.0 all locations or 60.0 all locations 
- 
                                    Manual Actuator Type And Quantity2 toggle 
- 
                                    Center To Center Distance Between Terminals Parallel To Length1.909 inches minimum and 1.971 inches maximum 
- 
                                    Body Width1.469 inches minimum and 1.531 inches maximum 
- 
                                    Boss Height0.109 inches minimum and 0.171 inches maximum 
- 
                                    Terminal Type And Quantity4 threaded stud 
- 
                                    External Actuator Linkage Arrangementone and two linked 
- 
                                    Features Providedhigh inrush protection 
- 
                                    Case Materialplastic 
- 
                                    End Item Identificationmissle, minuteman lgm-30, test set 
- 
                                    ~1on certain environmental and performance requ 
Related Parts by Category
Related Manufacturers
 
     Certified to
        Certified toAS6081 Methods
 
     
     
    
    
    
     

 
    