NSN: 5925-01-547-2880
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Pole Quantity
3
 - 
                                    
Circuit Protection Type
overcurrent all locations
 - 
                                    
Reset Method
manual
 - 
                                    
Trip Release Ambient Temp Rating
40.0 deg celsius nominal all locations
 - 
                                    
Body Height
3.380 inches nominal
 - 
                                    
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
65000.0 ac all locations
 - 
                                    
Body Width
4.130 inches nominal
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.500 inches nominal
 - 
                                    
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
 - 
                                    
Trip Release Method
thermal-magnetic all locations
 - 
                                    
Main Contact Tripping Mechanism Type
nontrip free
 - 
                                    
Body Style
multipole-single actuator type
 - 
                                    
Special Features
sealed with non-interchangable trip units; suitable for reverse feed use; includes terminals on load end only
 - 
                                    
Unthreaded Mounting Hole Diameter
0.164 inches nominal
 - 
                                    
Mounting Facility Type And Quantity
4 unthreaded hole
 - 
                                    
Boss Height
0.125 inches nominal
 - 
                                    
Frequency In Hertz
60.0 all locations or 50.0 all locations
 - 
                                    
Body Length
6.000 inches nominal
 - 
                                    
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations and 125.0 dc all locations
 - 
                                    
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
 - 
                                    
Terminal Type And Quantity
3 screw
 - 
                                    
Center To Center Distance Between Terminals Parallel To Length
5.062 inches nominal
 - 
                                    
Maximum Continuous Load Current Rating Per Pole
300.0 amperes ac all locations
 - 
                                    
Part Name Assigned By Controlling Agency
molded case circuit breaker f-frame, 10-225 amp, type ed
 - 
                                    
End Item Identification
hemp endurable power system
 - 
                                    
Case Material
plastic
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    