NSN: 5925-01-575-7054
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Overall Length
1.375 nominal inches
-
Reset Method
manual
-
Part Name Assigned By Controlling Agency
cage: snapak series magnetic circuit protector, push-pull, 2 pole, fast delay dc-50/60hz, black, no outer hardware desired, horizontal mount, vde and ccc approved
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc all locations
-
Trip Release Characteristic
time delay all locations
-
End Item Identification
10256c/brr-6 trident, control indicator; 10256d/brr-6 trident, control indicator
-
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct all locations and 8.000 maximum at 200 pct all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc all locations
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic all locations
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Special Features
push-pull actuator has white band visible in off position onl; knife blade terminals are 0.375 in. long with single hole
-
Manual Actuator Type And Quantity
1 push-pull
-
Body Style
multipole-single actuator type
-
Terminal Type And Quantity
4 knife blade
-
Main Contact Tripping Mechanism Type
trip free
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes dc all locations
-
Frequency In Hertz
50.0 all locations or 60.0 all locations
-
Thread Series Designator
unef
-
Overall Diameter
1.304 inches nominal
-
Case Material
plastic