NSN: 5930-01-088-4805
Switches
SWITCH,ROTARY
SWITCH,ROTARY
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Load Current Rating
5.0 amperes resistive load ac at sea level and 2.0 amperes inductive load ac at sea level
-
Overall Length
5.895 inches minimum and 6.041 inches maximum
-
Terminal Type
tab, solder lug
-
Switch Contact Basic Design
nonpile-up symmetrical
-
Nominal Thread Size
0.375 inches 1st mounting facility
-
Shaft Diameter
0.248 inches minimum single actuator and 0.251 inches maximum single actuator
-
Rotor Through Connection Quantity
1 each section
-
Contact Voltage Rating In Volts
28.0 dc at sea level
-
Nonturn Device Radius
0.360 inches minimum at 3:00 o'clock and 0.390 inches maximum at 3:00 o'clock
-
Longest Horizontal Distance Between Mounting Centers
0.990 inches minimum 2nd mounting facility and 1.010 inches maximum 2nd mounting facility
-
Individual Section Quantity
12
-
Nominal Thread Size
0.073 inches 2nd mounting facility
-
Shaft Flat/Slot Angular Location
195.0 degrees from nonturn device single actuator
-
Contact Load Current Rating
1.0 amperes resistive load dc at sea level
-
Flat Height
0.215 inches minimum single actuator and 0.223 inches maximum single actuator
-
Pole Quantity
1 each section front
-
Switch Actuator Stop Device Type
fixed stop single actuator
-
Throw Quantity
6 each section rear
-
Overall Diameter
1.254 inches minimum and 1.314 inches maximum
-
Thread Series Designator
unef 1st mounting facility
-
Switch Actuator Indexing Position Quantity
6 single actuator
-
Thread Class
2a 1st mounting facility
-
Switch Actuator Positioning Increment
45.0 degrees single actuator
-
Contact Voltage Rating In Volts
115.0 ac at sea level
-
Thread Series Designator
unf 2nd mounting facility
-
Contact Switching Action
breaks before makes each section rear
-
Precious Material And Location
contacts silver
-
Mounting Method
threaded bushing 1st mounting facility
-
Err Default
err default
-
Err Default
err default and err default
-
Mounting Facility Pattern
two position in-line 2nd mounting facility
-
Operating Temp Range
-55.0/+125.0 deg celsius
-
Precious Material
silver
-
Style Designator
tap, circular, bushing mount
-
Thread Class
2a 2nd mounting facility
-
Mounting Method
threaded stud 2nd mounting facility
-
Shaft Type
round, flatted single actuator
-
First Flat Length
0.230 inches minimum single actuator and 0.270 inches maximum single actuator
-
Shaft Length
0.417 inches minimum single actuator and 0.457 inches maximum single actuator
-
Nonturn Device Type
tab at 3:00 o'clock
-
Hazardous Locations/Environmental Protection
moisture resistant
Related Parts by Category
Related Manufacturers


AS6081 Methods