NSN: 5930-01-363-4229
Switches
SWITCH,THERMOSTATIC
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-s-24236 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
~1
data on certain environmental and performanc
-
Contact Stimulus Rating
162.00 actuation point minimum degrees fahrenheit and 178.00 actuation point maximum degrees fahrenheit and 149.00 deactuation point minimum degrees fahrenheit and 161.00 deactuation point maximum degrees fahrenheit
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 400.0 deg fahrenheit maximum
-
Contact Load Current Rating
2.0 amperes resistive load first voltage and 1.0 amperes inductive load second voltage and 2.0 amperes resistive load second voltage and 1.0 amperes inductive load first voltage and 0.5 amperes lamp load first voltage
-
Body Diameter
0.560 inches minimum and 0.640 inches maximum
-
Contact Adjustability
actuation point not adjustable and deactuation point not adjustable
-
Specification/Standard Data
81349-mil-s-24236/24 government specification
-
Overall Height
0.526 inches maximum
-
Style Designator
disc w/flange
-
Distance Between Mounting Facility Centers
0.930 inches minimum and 0.944 inches maximum
-
Overall Length
1.160 inches minimum and 1.260 inches maximum
-
Mounting Method
slot and bracket and unthreaded hole
-
Terminal Type
tab, solder lug
-
Body Height
0.366 inches minimum and 0.431 inches maximum
-
Temp Sensing Element Type
internal sensor
-
Media For Which Designed
gas or liquid
-
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage
-
Frequency In Hertz
60.0 first voltage
-
Nonpile-Up Contact Arrangement
1 pole, double throw, one position momentary
-
Mounting Slot Width
0.133 inches minimum and 0.147 inches maximum
-
Unthreaded Mounting Hole Diameter
0.133 inches minimum and 0.147 inches maximum
-
Contact Load Current Rating
0.5 amperes lamp load second voltage
-
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage
-
Mounting Facility Pattern
two position in-line
-
Contact Action Stimulus
increase
Related Parts by Category
Related Manufacturers


AS6081 Methods