NSN: 5945-00-257-7853

Technical Characteristics

  • Main Contact Load Current Rating At Maximum Rated Voltage

    3.0 amperes ac inductive load and 1.5 amperes dc inductive load

  • Terminal Type And Quantity

    14 wire hook all functions

  • Duty Type

    continuous

  • Time Delay

    0.025 seconds maximum fixed operate time

  • Cubic Measure

    5.567 cubic inches

  • Thread Series Designator

    unc single mounting facility

  • Coil Quantity

    1

  • Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle

    1.188 inches nominal single mounting facility

  • Contact Material

    silver

  • Purpose For Which Designed

    general

  • Winding Dc Resistance Rating

    450.0 ohms nominal single winding

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    0.938 inches nominal single mounting facility

  • Overall Length

    1.625 inches maximum

  • Nonpile-Up Main Contact Arrangement

    4 pole, double throw, one position momentary

  • Time Delay

    0.01 seconds maximum fixed release time

  • Mounting Facility Pattern

    triangle single mounting facility

  • Thread Direction

    right-hand single mounting facility

  • Case Material

    metal

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 26.5 dc

  • Thread Class

    2a single mounting facility

  • Winding Quantity

    1

  • Thread Quantity Per Inch

    32 single mounting facility

  • Arc Quenching Method

    air

  • Environmental Protection

    hermetic

  • Operating Voltage Rating And Type At Specified Temp

    26.5 volts dc 25 deg celsius single winding

  • Overall Height

    2.437 inches maximum

  • Overall Width

    1.406 inches maximum

  • Storage Type

    general purpose warehouse

  • Precious Material

    silver

  • Mounting Facility Type And Quantity

    3 threaded stud single mounting facility

  • Precious Material And Location

    contacts silver

  • Nominal Thread Size

    0.138 inches single mounting facility

  • Fragility Factor

    moderately rugged

  • Main Contact Load Current Rating At Maximum Rated Voltage

    3.0 amperes ac resistive load and 3.0 amperes dc resistive load

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...