NSN: 5945-01-271-0922

Relays and Solenoids

RELAY,ELECTROMAGNETIC

5945 - Relays and Solenoids

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • ~1

    data on certain environmental and performanc

  • Main Contact Load Current Rating At Maximum Rated Voltage

    200.0 milliamperes dc inductive load

  • Cubic Measure

    0.055 cubic inches

  • Operating Voltage Rating And Type At Specified Temp

    12.0 volts dc 25 deg celsius single winding

  • Time Delay

    0.0075 seconds maximum fixed release time

  • Overall Length

    0.370 inches maximum

  • Duty Type

    continuous

  • Main Contact Load Current Rating At Maximum Rated Voltage

    500.0 milliamperes ac resistive load and 1.0 amperes dc resistive load

  • Arc Quenching Method

    air

  • Winding Quantity

    1

  • Main Contact Load Current Rating At Maximum Rated Voltage

    100.0 milliamperes dc lamp load

  • Mounting Facility Type And Quantity

    1 terminal single mounting facility

  • Case Material

    metal

  • Special Features

    failure rate level 0.1 percent

  • Time Delay

    0.004 seconds maximum fixed operate time

  • End Item Identification

    5895012527359 terminal set

  • Specification/Standard Data

    81349-mil-r-39016/43 government specification

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Features Provided

    polarized and coil voltage suppression

  • Winding Dc Resistance Rating

    800.0 ohms nominal single winding

  • Overall Height

    0.400 inches maximum

  • Purpose For Which Designed

    general

  • Terminal Type And Quantity

    8 wire lead all functions

  • Coil Quantity

    1

  • Test Data Document

    81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Energizing Element Power Rating

    60.0 milliwatts

  • Overall Width

    0.370 inches maximum

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Nonpile-Up Main Contact Arrangement

    2 pole, double throw, one position momentary

  • Environmental Protection

    hermetic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...