NSN: 5945-01-278-7149
Relays and Solenoids
RELAY,ELECTROMAGNETIC
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
- 
                                    
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
 - 
                                    
~1
data on certain environmental and performance
 - 
                                    
Mounting Facility Pattern
in-line single mounting facility
 - 
                                    
Duty Type
continuous
 - 
                                    
Overall Width
0.390 inches minimum and 0.410 inches maximum
 - 
                                    
Winding Dc Resistance Rating
500.0 ohms nominal single winding
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac motor load and 1.0 amperes dc motor load
 - 
                                    
Coil Quantity
1
 - 
                                    
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
 - 
                                    
Purpose For Which Designed
general
 - 
                                    
Terminal Type And Quantity
8 pin all functions
 - 
                                    
Overall Length
1.260 inches minimum and 1.280 inches maximum
 - 
                                    
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
 - 
                                    
Special Features
failure rate level 0.3 percent
 - 
                                    
Features Provided
polarized
 - 
                                    
Case Material
metal
 - 
                                    
Specification/Standard Data
81349-mil-r-6106/27 government specification
 - 
                                    
Winding Quantity
1
 - 
                                    
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes ac lamp load and 1.0 amperes dc lamp load
 - 
                                    
Arc Quenching Method
air
 - 
                                    
Time Delay
0.004 seconds maximum fixed operate and release time
 - 
                                    
Nominal Operating Current Rating And Type
65.0 milliamperes dc single winding
 - 
                                    
Environmental Protection
hermetic
 - 
                                    
Center To Center Distance Between Mounting Facilities Parallel To Length
1.062 inches minimum single mounting facility and 1.078 inches maximum single mounting facility
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
 - 
                                    
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
 - 
                                    
Cubic Measure
0.336 cubic inches
 - 
                                    
Criticality Code Justification
feat
 - 
                                    
Storage Type
general purpose warehouse
 - 
                                    
Overall Height
0.620 inches minimum and 0.640 inches maximum
 - 
                                    
End Item Identification
6920011953628
 - 
                                    
Mounting Slot Width
0.133 inches nominal single mounting facility
 - 
                                    
Fragility Factor
moderately rugged
 - 
                                    
Main Contact Load Current Rating At Maximum Rated Voltage
3.0 amperes ac inductive load and 3.0 amperes dc inductive load
 
Related Parts by Category
Related Manufacturers
    
        Certified toAS6081 Methods
    
    
    
    
    
    

    