NSN: 5945-01-301-4814
Relays and Solenoids
RELAY,ELECTROMAGNETIC
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Mounting Facility Type And Quantity
3 slotted hole single mounting facility
-
Case Material
metal
-
Specification/Standard Data
81349-mil-r-6106/28 government specification
-
Frequency In Hertz
400.0 nominal
-
Mounting Facility Pattern
triangle single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Operating Voltage Rating And Type At Specified Temp
29.0 volts dc 25 deg celsius single winding
-
Overall Width
0.810 inches maximum
-
Nonpile-Up Main Contact Arrangement
4 pole, double throw, one position momentary
-
Special Features
established reliability 0.100 percent
-
Purpose For Which Designed
general
-
Overall Length
1.280 inches maximum
-
Coil Quantity
1
-
Cubic Measure
0.664 cubic inches
-
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac motor load and 2.0 amperes dc motor load
-
Winding Dc Resistance Rating
400.0 ohms nominal single winding
-
Terminal Type And Quantity
16 wire hook all functions
-
Duty Type
continuous
-
~1
data on certain environmental and performance
-
Main Contact Load Current Rating At Maximum Rated Voltage
3.0 amperes ac inductive load and 3.0 amperes dc inductive load
-
Fragility Factor
moderately rugged
-
Storage Type
general purpose warehouse
-
Criticality Code Justification
feat
-
Overall Height
0.640 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.062 inches minimum single mounting facility and 1.078 inches maximum single mounting facility
-
Time Delay
0.006 seconds maximum fixed operate and release time
-
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
-
Environmental Protection
hermetic
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.490 inches minimum single mounting facility and 0.510 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
1.0 amperes ac lamp load and 1.0 amperes dc lamp load
-
Mounting Slot Width
0.131 inches minimum single mounting facility and 0.151 inches maximum single mounting facility
-
Winding Quantity
1
Related Parts by Category
Related Manufacturers


AS6081 Methods



