NSN: 5945-01-309-9224

Relays and Solenoids

RELAY,ELECTROMAGNETIC

5945 - Relays and Solenoids

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Features

    failure rate of 0.100 percent

  • Storage Type

    general purpose warehouse

  • Criticality Code Justification

    feat

  • Nonpile-Up Main Contact Arrangement

    2 pole, double throw, one position momentary

  • Environmental Protection

    hermetic

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-r-39016 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Terminal Type And Quantity

    8 wire lead all functions

  • Coil Quantity

    1

  • Main Contact Load Current Rating At Maximum Rated Voltage

    200.0 milliamperes dc inductive load

  • End Item Identification

    5895-01-188-0365 coder group

  • Overall Width

    0.335 inches maximum

  • Overall Length

    0.370 inches maximum

  • Duty Type

    continuous

  • Time Delay

    0.002 seconds maximum fixed operate time

  • Main Contact Load Current Rating At Maximum Rated Voltage

    500.0 milliamperes ac resistive load and 1.0 amperes dc resistive load

  • Arc Quenching Method

    air

  • Winding Quantity

    1

  • Main Contact Load Current Rating At Maximum Rated Voltage

    100.0 milliamperes dc lamp load

  • Mounting Facility Type And Quantity

    1 terminal single mounting facility

  • Main Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Overall Height

    0.300 inches maximum

  • Operating Voltage Rating And Type At Specified Temp

    5.0 volts dc 25 deg celsius single winding

  • Specification/Standard Data

    81349-mil-r-39016/19 government specification

  • Winding Dc Resistance Rating

    39.0 ohms nominal single winding

  • Cubic Measure

    0.037 cubic inches

  • Time Delay

    0.004 seconds maximum fixed release time

  • Purpose For Which Designed

    general

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...