Technical Characteristics
-
Fragility Factor
moderately rugged
-
Specification/Standard Data
81349-mil-r-6106/19 government specification
-
Storage Type
general purpose warehouse
-
Cubic Measure
0.543 cubic inches
-
Environmental Protection
hermetic
-
Mounting Facility Type And Quantity
2 slotted hole single mounting facility
-
Winding Quantity
1
-
Overall Width
1.010 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
25.0 amperes ac resistive load and 25.0 amperes dc resistive load
-
Time Delay
0.01 seconds nominal fixed operate and release time
-
Overall Length
1.025 inches maximum
-
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac motor load and 10.0 amperes dc motor load
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Mounting Slot Width
0.140 inches minimum single mounting facility and 0.160 inches maximum single mounting facility
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type
-
Nonpile-Up Main Contact Arrangement
1 pole, double throw, one position momentary
-
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac lamp load and 5.0 amperes dc lamp load
-
Purpose For Which Designed
general
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
-
Coil Quantity
1
-
Overall Height
0.525 inches maximum
-
Winding Dc Resistance Rating
288.0 ohms minimum single winding and 352.0 ohms maximum single winding
-
Terminal Type And Quantity
5 pin all functions
-
End Item Identification
harm cntl pnl
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.396 inches minimum single mounting facility and 1.446 inches maximum single mounting facility
-
Main Contact Load Current Rating At Maximum Rated Voltage
15.0 amperes ac inductive load and 12.0 amperes dc inductive load
-
Duty Type
continuous
-
Mounting Facility Pattern
in-line single mounting facility
-