Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Winding Power Rating
48.3 volts-amperes single component 3rd secondary
-
Inclosure Type
open
-
Winding Function And Quantity
1 primary single component and 6 secondary single component
-
Winding Power Rating
45.4 volts-amperes single component 2nd secondary
-
Mounting Method
bracket single group and slot single group
-
Winding Power Rating
238.7 volts-amperes single component 1st secondary
-
Maximum Operating Temp
155.0 deg celsius
-
Special Features
one primary winding; six secondary windings
-
Body Length
2.970 inches minimum and 3.030 inches maximum
-
Body Height
1.280 inches minimum and 1.340 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.740 inches minimum single mounting facility single center group and 2.760 inches maximum single mounting facility single center group
-
Winding Operating Voltage
23.00 ac pounds per hour wet single component 1st secondary
-
Maximum Transformer Power Rating
446.5 volt-ampere single component
-
Winding Power Rating
24.1 volts-amperes single component 4th secondary
-
Terminal Type And Quantity
22 wire lead
-
Overall Width
2.220 inches minimum and 2.280 inches maximum
-
Mounting Slot Width
0.100 inches minimum single group and 0.160 inches maximum single group
-
Winding Operating Voltage
10.50 ac pounds per hour wet single component 2nd secondary
-
Winding Operating Current
1.8 amperes nominal b single component 3rd secondary
-
Winding Operating Voltage
113.00 ac pounds per hour dry single component single primary and 195.00 ac pounds per hour with retaining chain single component single primary
-
Winding Operating Current
900.0 milliamperes nominal b single component 4th secondary
-
Frequency Rating
400.0 hertz nominal single component
-
Reliability Indicator
not established
-
Transformer Winding Connection Type
delta-delta
-
Winding Operating Voltage
15.50 ac pounds per hour wet single component 4th secondary
-
Winding Operating Voltage
15.50 ac pounds per hour wet single component 3rd secondary
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Winding Operating Current
6.0 amperes nominal b single component 1st secondary
-
Input-Output Phase Relationship
three phase to three phase single component
-
Winding Operating Current
2.5 amperes nominal b single component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.927 inches minimum single mounting facility single center group and 1.947 inches maximum single mounting facility single center group