NSN: 5950-00-331-3903
Coils and Transformers
TRANSFORMER,POWER
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.250 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.125 inches nominal
-
Body Length
1.875 inches nominal
-
Body Width
1.625 inches nominal
-
Body Height
1.593 inches nominal
-
Inclosure Type
hermetically sealed
-
Mounting Facility Quantity
4
-
Winding Function And Quantity
1 primary and 1 secondary
-
Winding Operating Current
600.0 milliamperes ac maximum
-
Winding Operating Voltage
115.00 ac volts nominal
-
Special Features
case metal material
-
Frequency Rating
50.0 hertz minimum and 60.0 hertz maximum
-
Input-Output Phase Relationship
single phase to single phase
-
Winding Shielding Method
internal shield brought out to terminal
-
Mounting Method
flange and unthreaded hole
-
Winding Tap Location
center tap
-
Winding Operating Voltage
6.30 ac volts nominal
-
Terminal Type And Quantity
5 standoff,solder lug and 1 tab,solder lug